Physical and Environmental |
| Weight: |
2.8 kg (terminal with battery) |
| Dimensions: |
27.5 cm D x 34.5 cm W x 5.0 cm H |
| Battery Life*: |
Transmit: 162 megabytes Receive: 864 megabytes 36 hours standby time |
| Humidity: |
95% RH at +40° C |
| Temperature: |
-25° C to +60° C operating -25° C to +60° C storage (w/ battery) |
| Water and Dust: |
IP-55 standard |
| Wind: |
Operational 25 mph (40 km/h) |
| Survival: |
100 mph (160 km/h) |
| Ice: |
25 mm non-operational |
| |
| Power Consumption |
| Idle Mode: on regional beam with data context active, PC connected via Ethernet. Only periodic network signalling. Average power usage over 16 hours = 0.19 A at 19.7 V = 3.74 W |
| Idle mode + Ping: Send 4 pings and then allow unit to transition back to regional beam. Total time 200 sec. Average power = 3.87 W |
| Receive Mode: FTP get of 5 MB file at 160 kbps. Average power consumption = 5 W (max ~10 W) |
| Transmit Mode: FTP put of 5 MB file at 310 kbps. Average power consumption = 24 W (max ~30 W) |
| |
| Solar Compatible |
| Requires 55–60 W solar panel plus DC/DC power adapter to input 20 V to 9201 M2M terminal |
| * Actual performance will vary based upon a wide range of factors and actual usage. |