| Physical Interfaces |
Two 10/100BaseT Ethernet LAN RJ45 ports (independend subnets |
| |
One Serial port (RS-422 or RS-232) |
| |
One BNC interface for external 10 MHz reference |
| Satellite Specifications |
|
|
Frequency |
C-, Extended C-, X-, Ku-, Kaband |
|
DVB-S2 ACM Channel |
DVB-S2 with Adaptive Coding and Modulation or DVB-S |
|
DVB-S2 ACM Rate |
1–45 Msps (in 0.5 Msps steps) |
|
DVB-S2 ACM Modulation |
QPSK, 8PSK, 16APSK (Adaptive Modulation) |
|
DVB-S2 ACM Coding |
BCH with LDPC 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9, 9/10 (Adaptive Coding) |
|
FDMA/TDMA (IPoS) Channel Rate |
256 to 2048 ksps
(256 kbps to 9.6 Mbps) |
|
FDMA/TDMA (IPoS) Modulation: |
OQPSK |
|
FDMA/TDMA (IPoS) Channel Coding Rate |
Adaptive Coding 1/2, 2/3, 4/5 with TurboCode 1/2, 2/3, 4/5 and 9/10 with LDPC |
|
Error Rate (Receive) |
Quasi Error Free |
|
Error Rate (Transmit) |
10-5 PLR (equivolent to 10-7 or better) |
|
Interface to ODU |
Hughes Saturated Carrier BUC |
| Performance |
|
|
Packets per second |
5,000 |
|
UDP throughput |
45 Mbps |
|
TCP throughput |
15 Mbps |
|
Multicast throughput |
60 Mbps |
| Mechanical & Environmental |
|
|
1U rack mount unit for 19" rack |
|
| Weight |
5.5 lbs (2.5 kg) |
| Dimensions |
19" W x 1.75" H x 14" D (48.26 cm W x 4.45 cm H x 35.6 cm D) |
| Operating temperature |
IDU: +32º F (0º C) to +122º F (+50º C) |